How do I calculate the discharge head and the power of a pump?

The discharge head is the vertical distance between the axis of the pump and the free surface (or the outlet point) of the discharge tank. Added to the suction head, it forms the static head the pump must overcome; adding the head losses of the network and any pressure difference between the tanks gives the total dynamic head TDH. The useful (hydraulic) power is ρ g Q TDH and the power absorbed by the motor follows from the pump efficiency. Example: 20 m³/h of water, 2 m of suction head, 20 m of discharge head and 3 m of head losses: TDH of 25 m, useful power 1.36 kW, absorbed power 2.1 kW with an efficiency of 65 %. The discharge head does not change with the flow rate; the head losses, however, grow with its square.

Total head and power formulas

TDH = Hsuction + Hdischarge + ΔHlosses + P₂ − P₁ρ × g     Puseful = ρ × g × Q × TDH     Pabsorbed = Pusefulη
  • Hdischarge: discharge head, in m, from the pump axis to the surface of the discharge tank or to the outlet point
  • Hsuction: suction head, in m, positive if the pump is above the suction tank, negative with flooded suction
  • ΔHlosses: head losses of the whole pipework at flow rate Q, in m of fluid
  • P₁, P₂: pressures in the suction and discharge tanks, in Pa (0 if open to the atmosphere); ρ density in kg/m³; g = 9.81 m/s²
  • Q: flow rate, in m³/s; Puseful and Pabsorbed: hydraulic and shaft powers, in W; η: pump efficiency (0.5 to 0.85)

TDH and pump powers against discharge head

Water at 998 kg/m³, Q = 20 m³/h, suction head 2 m, head losses 3 m (counted on the discharge side), tanks open to the atmosphere, efficiency 65 %
Discharge head HdischargeTDHUseful powerAbsorbed powerPressure at the discharge flange
5 m10 m544 W837 W0.78 bar
10 m15 m816 W1,255 W1.27 bar
20 m25 m1,360 W2,092 W2.25 bar
30 m35 m1,904 W2,929 W3.23 bar
50 m55 m2,992 W4,602 W5.19 bar

Detailed explanations and calculation in Mecaflux

discharge height, in a pumping system is the vertical dimension, measured between the surface of the discharge tank and the axis of the pump.

The discharge height plays a key role in the effective power of the pump

with Mecaflux standard

.height of discharge power consumption and power output

Frequently asked questions

Does the discharge head depend on the length of the pipe?

No: it is a purely vertical distance, measured between the pump axis and the level at which the water arrives, whatever the route of the pipework. The length of the pipe enters the head losses, which are added to the static head in the TDH: 100 m of horizontal pipe add nothing to the discharge head, but a few metres of head loss at the rated flow.

What is the discharge head if the pipe ends in the open air or in a pressurised tank?

If the pipe discharges into the open air above the tank, the discharge head is measured up to the outlet point (the free fall afterwards does not count). If the tank is pressurised or closed, add its pressure converted into fluid height: 1 bar corresponds to 10.2 m of water. If the pipe dips below the tank level, it is the level of the free surface that counts, not the pipe outlet.

How do I convert head into pressure, and vice versa?

With P = ρ g H: for water, 10 m of head equal 0.98 bar, and 1 bar equals 10.2 m. A pump is rated in head (m of fluid) because head does not depend on the fluid pumped: the same pump at the same flow gives the same head with water or oil, but a pressure and an absorbed power proportional to the density.

How do I calculate the TDH and the pump power of my own installation?

In the pump and turbine systems interface of Mecaflux Standard you enter the suction and discharge heads, the tank pressures and the head losses from the inventory, and the software displays the TDH, the available NPSH and the useful and absorbed powers; the pump editor and the graphical analysis then find the operating point of the chosen pump. For a pumping installation to design or diagnose, Mecaflux carries out the study of your project and delivers the calculation report, or offers training on the software applied to your own installation.