Page contents
  1. What is the Blasius formula for the friction factor?
  2. Blasius formula
  3. Blasius friction factor compared with the smooth-pipe law
  4. Detailed explanations and calculation in Mecaflux
  5. Frequently asked questions

What is the Blasius formula for the friction factor?

The Blasius formula gives the friction factor λ of a smooth pipe in moderately turbulent flow, for a Reynolds number between 3,000 and 10⁵: λ = 0.316 / Re0.25. It is explicit, unlike the Colebrook-White equation which requires an iterative solution, but it ignores roughness: it applies only to hydraulically smooth pipes (glass, copper, PVC, polished stainless steel) and it underestimates losses beyond Re = 10⁵.

Blasius formula

λ = 0.316⁴√Re = 0.316 × Re−0.25     (3,000 < Re < 10⁵, smooth pipe)
ΔH = λ × LD × V²2 g
  • λ (lambda): friction factor for major head loss, dimensionless
  • Re: Reynolds number = V D / ν, dimensionless
  • ΔH: head loss in metres of fluid column (ΔP = ρ g ΔH, in Pa)
  • L, D: length and inside diameter of the pipe, in m; V: mean velocity, in m/s; g = 9.81 m/s²
  • Combining both formulas, the pressure drop varies as V1.75 and as D−1.25

Blasius friction factor compared with the smooth-pipe law

Reference: Prandtl-Kármán smooth-pipe law, 1/√λ = 2 log(Re √λ) − 0.8 (Colebrook-White with zero roughness)
Reynoldsλ Blasiusλ smooth pipe (reference)Deviation
4,0000.03970.0399−0.5 %
10,0000.03160.0309+2 %
20,0000.02660.0259+3 %
50,0000.02110.0209+1 %
100,0000.01780.0180−1 %
1,000,0000.01000.0116−14 % (outside the validity range)

Detailed explanations and calculation in Mecaflux

This formula is used to evaluate the coefficient of losses in turbulent flow moderate: (2000 < Re < 105)

l is the major head loss coefficient ,

Re is the number of Reynolds

Frequently asked questions

In which range is the Blasius formula valid?

For turbulent flow in a smooth pipe, from Re ≈ 3,000 to 4,000 up to Re = 10⁵; the deviation from the smooth-pipe law stays below 3 % there. Below Re = 2,000 the flow is laminar and Poiseuille's formula λ = 64 / Re applies; above 10⁵, Blasius underestimates λ and Colebrook-White or the Prandtl law must be used.

What is a hydraulically smooth pipe?

A pipe whose asperities stay buried in the viscous sublayer of the flow, so that roughness has no effect on head loss. This depends on the Reynolds number: a pipe is smooth as long as ε / D is below about 10⁻⁴ at Re = 10⁵, i.e. ε < 5 µm for a 50 mm pipe: glass, copper, PVC, polished stainless steel. Ordinary steel (ε = 50 µm) is no longer smooth at that Reynolds number.

How do I calculate a head loss with the Blasius formula?

Example: water at 20 °C (ν = 1.0 mm²/s) in a 20 mm copper tube at 1 m/s. Re = 1 × 0.02 / 10⁻⁶ = 20,000; λ = 0.316 / 20,0000.25 = 0.0266; loss per metre ΔP = λ / D × ρ V² / 2 = 0.0266 / 0.02 × 499 = 664 Pa/m, i.e. 6.6 mbar or 6.8 cm of water per metre of tube.

How do I calculate the head losses of my copper, PVC or stainless steel piping?

Mecaflux Standard applies Colebrook-White with the roughness of the chosen material (which reduces to Blasius for a smooth pipe), at the actual flow and temperature, and adds up the sections and fittings of the installation. For a complete network (heating, water, compressed air, process), Mecaflux carries out the study of your project and the calculation report, or offers training on the software applied to your own network.