Page contents
What is the Blasius formula for the friction factor?
The Blasius formula gives the friction factor λ of a smooth pipe in moderately turbulent flow, for a Reynolds number between 3,000 and 10⁵: λ = 0.316 / Re0.25. It is explicit, unlike the Colebrook-White equation which requires an iterative solution, but it ignores roughness: it applies only to hydraulically smooth pipes (glass, copper, PVC, polished stainless steel) and it underestimates losses beyond Re = 10⁵.
Blasius formula
- λ (lambda): friction factor for major head loss, dimensionless
- Re: Reynolds number = V D / ν, dimensionless
- ΔH: head loss in metres of fluid column (ΔP = ρ g ΔH, in Pa)
- L, D: length and inside diameter of the pipe, in m; V: mean velocity, in m/s; g = 9.81 m/s²
- Combining both formulas, the pressure drop varies as V1.75 and as D−1.25
Blasius friction factor compared with the smooth-pipe law
| Reynolds | λ Blasius | λ smooth pipe (reference) | Deviation |
|---|---|---|---|
| 4,000 | 0.0397 | 0.0399 | −0.5 % |
| 10,000 | 0.0316 | 0.0309 | +2 % |
| 20,000 | 0.0266 | 0.0259 | +3 % |
| 50,000 | 0.0211 | 0.0209 | +1 % |
| 100,000 | 0.0178 | 0.0180 | −1 % |
| 1,000,000 | 0.0100 | 0.0116 | −14 % (outside the validity range) |
Detailed explanations and calculation in Mecaflux
This formula is used to evaluate the coefficient of losses in turbulent flow moderate: (2000 < Re < 105)
l is the major head loss coefficient ,
Re is the number of Reynolds
Frequently asked questions
In which range is the Blasius formula valid?
For turbulent flow in a smooth pipe, from Re ≈ 3,000 to 4,000 up to Re = 10⁵; the deviation from the smooth-pipe law stays below 3 % there. Below Re = 2,000 the flow is laminar and Poiseuille's formula λ = 64 / Re applies; above 10⁵, Blasius underestimates λ and Colebrook-White or the Prandtl law must be used.
What is a hydraulically smooth pipe?
A pipe whose asperities stay buried in the viscous sublayer of the flow, so that roughness has no effect on head loss. This depends on the Reynolds number: a pipe is smooth as long as ε / D is below about 10⁻⁴ at Re = 10⁵, i.e. ε < 5 µm for a 50 mm pipe: glass, copper, PVC, polished stainless steel. Ordinary steel (ε = 50 µm) is no longer smooth at that Reynolds number.
How do I calculate a head loss with the Blasius formula?
Example: water at 20 °C (ν = 1.0 mm²/s) in a 20 mm copper tube at 1 m/s. Re = 1 × 0.02 / 10⁻⁶ = 20,000; λ = 0.316 / 20,0000.25 = 0.0266; loss per metre ΔP = λ / D × ρ V² / 2 = 0.0266 / 0.02 × 499 = 664 Pa/m, i.e. 6.6 mbar or 6.8 cm of water per metre of tube.
How do I calculate the head losses of my copper, PVC or stainless steel piping?
Mecaflux Standard applies Colebrook-White with the roughness of the chosen material (which reduces to Blasius for a smooth pipe), at the actual flow and temperature, and adds up the sections and fittings of the installation. For a complete network (heating, water, compressed air, process), Mecaflux carries out the study of your project and the calculation report, or offers training on the software applied to your own network.