Page contents
What is Poiseuille's formula for head loss in laminar flow?
In laminar flow, i.e. for a Reynolds number below about 2,000, the friction factor of a pipe is λ = 64 / Re, whatever the wall roughness. Substituted in the Darcy-Weisbach formula, this factor gives the Hagen-Poiseuille law: the pressure drop is proportional to viscosity, length and mean velocity, and inversely proportional to the square of the diameter. It therefore grows linearly with the flow rate, not with its square as in turbulent flow.
Poiseuille and Hagen-Poiseuille formulas
- λ (lambda): friction factor for major head loss, dimensionless, valid for Re < 2,000
- Re: Reynolds number, dimensionless
- V: mean fluid velocity, in m/s; D: inside diameter, in m; L: pipe length, in m
- ν (nu): kinematic viscosity, in m²/s; μ (mu): dynamic viscosity, in Pa·s (μ = ρ ν)
- ΔH: head loss in metres of fluid column; ΔP: pressure drop in Pa; Q: flow rate in m³/s; g = 9.81 m/s²
Laminar head loss examples
| Fluid | Diameter D | Velocity V | Reynolds | λ = 64 / Re | Pressure drop |
|---|---|---|---|---|---|
| VG 46 oil | 20 mm | 1 m/s | 435 | 0.147 | 3,200 Pa/m (0.37 m of oil per m) |
| VG 46 oil | 20 mm | 2 m/s | 870 | 0.074 | 6,400 Pa/m (twice, not four times) |
| VG 46 oil | 50 mm | 1 m/s | 1,087 | 0.059 | 512 Pa/m |
| Glycerine | 25 mm | 0.5 m/s | 11 | 5.7 | 36,100 Pa/m (0.36 bar/m) |
| Water | 2 mm (capillary) | 0.5 m/s | 1,000 | 0.064 | 4,000 Pa/m |
| Water | 20 mm | 0.05 m/s | 1,000 | 0.064 | 4 Pa/m |
Detailed explanations and calculation in Mecaflux
The poiseuille formula is used to evaluate the coefficient of pressure losses of laminar flow- laminar flow: (Re < 2000)
Frequently asked questions
Up to which Reynolds number is Poiseuille's formula valid?
Up to Re ≈ 2,000 (2,300 according to some authors). Between 2,000 and 4,000 the flow is transitional and unstable; above that it is turbulent and the Blasius formula (smooth pipe, Re < 10⁵) or the Colebrook-White equation, which includes roughness, is used. In water, laminar flow only exists at very low velocity or very small diameter: 5 cm/s in a 20 mm tube. It is common for oils, viscous fluids and microfluidics.
Why does roughness play no part in laminar flow?
Because the wall asperities are buried in the layer of fluid creeping along the wall; the head loss comes only from viscous shear between fluid layers, not from eddies shed by the roughness. A rusty pipe and a glass tube of the same diameter give the same laminar head loss.
How does laminar head loss vary with flow rate and diameter?
It is proportional to the flow rate: doubling the flow doubles the pressure drop (it would be multiplied by 3.5 to 4 in turbulent flow). At constant flow it varies as the inverse fourth power of the diameter: halving the diameter multiplies the pressure drop by 16. And it is proportional to viscosity, which for an oil can fall tenfold between 20 °C and 60 °C.
How do I calculate the head losses of my oil or viscous fluid circuit?
Mecaflux Standard itself selects Poiseuille or Colebrook according to the Reynolds number of each section, with the fluid viscosity at its temperature, and adds up the losses of the whole circuit in the head loss inventory. For a hydraulic, lubrication or viscous product transfer circuit, Mecaflux carries out the study of your project and the calculation report, or offers training on the software applied to your installation.